{"id":3199,"date":"2020-04-21T00:48:15","date_gmt":"2020-04-20T23:48:15","guid":{"rendered":"https:\/\/www.nickzom.org\/blog\/?p=3199"},"modified":"2024-03-31T07:57:07","modified_gmt":"2024-03-31T06:57:07","slug":"how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system","status":"publish","type":"post","link":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/","title":{"rendered":"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System"},"content":{"rendered":"<p><img decoding=\"async\" class=\"alignnone size-full wp-image-3202\" src=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/rated-static-head-mould.png\" alt=\"\" width=\"199\" height=\"254\" \/><\/p>\n<p>The image above represents rated static head (for Gating at Mould Parting). To calculate rated static head for gating at mould parting, two essential parameters are needed and these parameters are <strong>Height of the Sprue from its Top to the Point of Metal Entry into the Mould Cavity (H)<\/strong>\u00a0and\u00a0<strong>Height of the Casting (C).<\/strong><\/p>\n<h3><strong>The formula to Calculate rated static head (for gating at mould parting)<\/strong><\/h3>\n<p>The formula to calculate rated static head for gating at mould parting is:<\/p>\n<p>H<sub>s<\/sub>\u00a0= H \u2013\u00a0<sup>C<\/sup> \/\u00a0<sub>8<\/sub><\/p>\n<p>Where:<\/p>\n<p>H<sub>s<\/sub> = Rated Static Head (for gating at mould parting)<br \/>\nH = Height of the Sprue from its Top to the Point of Metal Entry into the Mould Cavity<br \/>\nC = Height of Casting<\/p>\n<p>Let\u2019s solve an example;<br \/>\nFind the rated static head (for gating at mould parting) when the height of the sprue from its top to the point of metal entry into the mould cavity is 11 and the height of casting is 19.<\/p>\n<p>This implies that;<\/p>\n<p>H = Height of the Sprue from its Top to the Point of Metal Entry into the Mould Cavity = 11<br \/>\nC = Height of Casting = 19<\/p>\n<p>H<sub>s<\/sub>\u00a0= H \u2013\u00a0<sup>C<\/sup> \/\u00a0<sub>8<\/sub><br \/>\nSo, H<sub>s<\/sub>\u00a0= 11 \u2013\u00a0<sup>19<\/sup>\u00a0\/\u00a0<sub>8<\/sub><br \/>\nH<sub>s<\/sub>\u00a0= 11 \u2013 2.375<br \/>\nH<sub>s<\/sub> = 8.625<\/p>\n<p>Therefore, the\u00a0<strong>rated static head (for gating at mould parting)<\/strong> is\u00a0<strong>8.625<\/strong><strong>\u00a0m.<\/strong><\/p>\n<h3><strong>Calculating the Height of the Sprue from its Top to the Point of Metal Entry into the Mould Cavity when the Rated Static Head (for gating at mould parting) and the Height of Casting are Given<\/strong><\/h3>\n<p>H = H<sub>s<\/sub>\u00a0+\u00a0<sup>C<\/sup> \/\u00a0<sub>8<\/sub><\/p>\n<p>Where;<\/p>\n<p>H = Height of the Sprue from its Top to the Point of Metal Entry into the Mould Cavity<br \/>\nH<sub>s<\/sub> = Rated Static Head (for gating at mould parting)<br \/>\nC = Height of Casting<\/p>\n<p>Let\u2019s solve an example;<br \/>\nFind the height of the sprue from its top to the point of metal entry into the mould cavity when the rated static head is 22 and the height of casting is 8.<\/p>\n<p>This implies that;<\/p>\n<p>H<sub>s<\/sub> = Rated Static Head (for gating at mould parting) = 22<br \/>\nC = Height of Casting = 8<\/p>\n<p>H = H<sub>s<\/sub>\u00a0+\u00a0<sup>C<\/sup> \/\u00a0<sub>8<\/sub><br \/>\nThen, H = 22 + <sup>8<\/sup> \/\u00a0<sub>8<\/sub><br \/>\nH = 22 + 1<br \/>\nH = 23<\/p>\n<p>Therefore, the\u00a0<strong>height of the sprue from its top to the point of metal entry into the mould cavity\u00a0<\/strong>is\u00a0<strong>23 m.<\/strong><\/p>\n<p>Read more:\u00a0<a href=\"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-in-top-gating-design-of-gating-system\/\">How to Calculate and Solve for Rated Static Head (in Top Gating) | Design of Gating System<\/a><\/p>\n<h3><strong>Calculating the Height of Casting when the Rated Static Head (for gating at mould parting) and the Height of the Sprue from its Top to the Point of Metal Entry into the Mould Cavity are Given.<\/strong><\/h3>\n<p>c = \u2013 (H<sub>s<\/sub> \u2013 H) 8<\/p>\n<p>Where;<\/p>\n<p>C = Height of Casting<br \/>\nH<sub>s<\/sub> = Rated Static Head (for gating at mould parting)<br \/>\nH = Height of the Sprue from its Top to the Point of Metal Entry into the Mould Cavity<\/p>\n<p>Let\u2019s solve an example;<br \/>\nFind the height of casting when the rated static head is 40 and the height of the sprue from its top of the point of metal entry into the mould cavity is 24.<\/p>\n<p>This implies that;<\/p>\n<p>H<sub>s<\/sub> = Rated Static Head (for gating at mould parting) = 40<br \/>\nH = Height of the Sprue from its Top to the Point of Metal Entry into the Mould Cavity = 24<\/p>\n<p>c = \u2013 (H<sub>s<\/sub> \u2013 H) 8<br \/>\nSo, c = \u2013 (40 \u2013 24) 8<br \/>\nc = \u2013 (16) 8<br \/>\nc = \u2013 128<\/p>\n<p>Therefore, the\u00a0<strong>height of casting\u00a0<\/strong>is\u00a0<strong>\u2013 128 m.<\/strong><\/p>\n<p>Read more:\u00a0<a href=\"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-in-bottom-gating-design-of-gating-system\/\">How to Calculate and Solve for Rated Static Head (in Bottom Gating) | Design of Gating System<\/a><\/p>\n<h3><strong>How to Calculate Rated Static Head (for Gating at Mould Parting) With Nickzom Calculator<\/strong><\/h3>\n<p>Nickzom Calculator \u2013\u00a0<strong>The Calculator Encyclopedia<\/strong> is capable of calculating the rated static head (for gating at mould parting).<\/p>\n<p>To get the answer and workings of the rated static head (for gating at mould parting) using the <strong>Nickzom Calculator \u2013 The Calculator Encyclopedia.\u00a0<\/strong>First, you need to obtain the app.<\/p>\n<p>You can get this app via any of these means:<\/p>\n<p><strong>Web<\/strong>\u00a0\u2013\u00a0<a href=\"https:\/\/www.nickzom.org\/calculator-plus\">https:\/\/www.nickzom.org\/calculator-plus<\/a><\/p>\n<p>To get access to the\u00a0<strong>professional\u00a0<\/strong>version via web, you need to\u00a0<strong>register<\/strong>\u00a0and\u00a0<strong>subscribe\u00a0<\/strong>for<strong>\u00a0NGN 1,500\u00a0<\/strong>per<strong>\u00a0annum<\/strong>\u00a0to have utter access to all functionalities.<br \/>\nYou can also try the\u00a0<strong>demo\u00a0<\/strong>version via\u00a0<a href=\"https:\/\/www.nickzom.org\/calculator\">https:\/\/www.nickzom.org\/calculator<\/a><\/p>\n<p><strong>Android (Paid)<\/strong>\u00a0\u2013\u00a0<a href=\"https:\/\/play.google.com\/store\/apps\/details?id=org.nickzom.nickzomcalculator\">https:\/\/play.google.com\/store\/apps\/details?id=org.nickzom.nickzomcalculator<\/a><br \/>\n<strong>Android (Free)<\/strong>\u00a0\u2013\u00a0<a href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nickzom.nickzomcalculator\">https:\/\/play.google.com\/store\/apps\/details?id=com.nickzom.nickzomcalculator<\/a><br \/>\n<strong>Apple (Paid)<\/strong>\u00a0\u2013\u00a0<a href=\"https:\/\/itunes.apple.com\/us\/app\/nickzom-calculator\/id1331162702?mt=8\">https:\/\/itunes.apple.com\/us\/app\/nickzom-calculator\/id1331162702?mt=8<\/a><br \/>\nOnce, you have obtained the calculator encyclopedia app, proceed to the\u00a0<strong>Calculator Map,\u00a0<\/strong>then click on\u00a0<strong>Materials &amp; Metallurgical<\/strong><b>\u00a0<\/b>under\u00a0<strong>Engineering<\/strong><strong>.<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-3160 size-full\" src=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1095-2.png\" alt=\"\" width=\"1366\" height=\"768\" srcset=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1095-2.png 1366w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1095-2-300x169.png 300w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1095-2-1024x576.png 1024w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1095-2-768x432.png 768w\" sizes=\"(max-width: 1366px) 100vw, 1366px\" \/><\/p>\n<p>Now, Click on\u00a0<strong>Foundry Technology<\/strong><strong>\u00a0u<\/strong>nder\u00a0<strong>Material &amp; Metallurgical<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-3159 size-full\" src=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1145.png\" alt=\"\" width=\"1366\" height=\"768\" srcset=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1145.png 1366w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1145-300x169.png 300w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1145-1024x576.png 1024w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1145-768x432.png 768w\" sizes=\"(max-width: 1366px) 100vw, 1366px\" \/><\/p>\n<p>Now, Click on\u00a0<strong>Design of Gating System\u00a0<\/strong>under\u00a0<strong>Foundry Technology<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-3158 size-full\" src=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1146.png\" alt=\"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System\" width=\"1366\" height=\"768\" srcset=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1146.png 1366w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1146-300x169.png 300w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1146-1024x576.png 1024w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1146-768x432.png 768w\" sizes=\"(max-width: 1366px) 100vw, 1366px\" \/><\/p>\n<p>Then, Click on <strong>Rated Static Head (for gating at mould parting)<\/strong><strong>\u00a0<\/strong>under\u00a0<strong>Design of Gating System<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-3206 size-full\" src=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1168.png\" alt=\"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System\" width=\"1366\" height=\"768\" srcset=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1168.png 1366w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1168-300x169.png 300w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1168-1024x576.png 1024w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1168-768x432.png 768w\" sizes=\"(max-width: 1366px) 100vw, 1366px\" \/><\/p>\n<p>The screenshot below displays the page or activity to enter your values, to get the answer for the rated static head (for gating at mould parting) according to the respective parameters which are the <strong>Height of the Sprue from its Top to the Point of Metal Entry into the Mould Cavity (H)<\/strong> and <strong>Height of the Casting (C).<\/strong><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-3205 size-full\" src=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1169.png\" alt=\"\" width=\"1366\" height=\"768\" srcset=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1169.png 1366w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1169-300x169.png 300w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1169-1024x576.png 1024w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1169-768x432.png 768w\" sizes=\"(max-width: 1366px) 100vw, 1366px\" \/><\/p>\n<p>Now, enter the values appropriately and accordingly for the parameters as required by the <strong>Height of the Sprue from its Top to the Point of Metal Entry into the Mould Cavity (H) <\/strong>is <strong>11<\/strong>\u00a0and <strong>Height of the Casting (C)<\/strong> is <strong>19<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-3204 size-full\" src=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1170.png\" alt=\"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System\" width=\"1366\" height=\"768\" srcset=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1170.png 1366w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1170-300x169.png 300w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1170-1024x576.png 1024w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1170-768x432.png 768w\" sizes=\"(max-width: 1366px) 100vw, 1366px\" \/><\/p>\n<p>Finally, Click on Calculate<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-3203 size-full\" src=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1171.png\" alt=\"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System\" width=\"1366\" height=\"768\" srcset=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1171.png 1366w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1171-300x169.png 300w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1171-1024x576.png 1024w, https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/Screenshot-1171-768x432.png 768w\" sizes=\"(max-width: 1366px) 100vw, 1366px\" \/><\/p>\n<p>As you can see from the screenshot above,\u00a0<strong>Nickzom Calculator<\/strong>\u2013 The Calculator Encyclopedia solves for the rated static head (for gating at mould parting) and presents the formula, workings and steps too.<\/p>\n","protected":false},"excerpt":{"rendered":"The image above represents rated static head (for Gating at Mould Parting). To calculate rated static head for&hellip;","protected":false},"author":5,"featured_media":13618,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_lmt_disableupdate":"","_lmt_disable":"","_sitemap_exclude":false,"_sitemap_priority":"","_sitemap_frequency":"","_yoast_wpseo_focuskw_text_input":"","csco_display_header_overlay":false,"csco_singular_sidebar":"","csco_page_header_type":"","footnotes":""},"categories":[47],"tags":[870,60,871,904,899,543,905],"class_list":["post-3199","post","type-post","status-publish","format-standard","has-post-thumbnail","category-engineering","tag-design-of-gating-system","tag-engineering","tag-foundry-technology","tag-height-of-the-cavity","tag-height-of-the-sprue-from-its-top-to-the-point-of-metal-entry-into-the-mould-cavity","tag-materials-and-metallurgical","tag-rated-static-head-for-gating-at-mould-parting","cs-entry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System<\/title>\n<meta name=\"description\" content=\"Learn How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) in Design of Gating System with formulas and workings\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System\" \/>\n<meta property=\"og:description\" content=\"Learn How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) in Design of Gating System with formulas and workings\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/\" \/>\n<meta property=\"og:site_name\" content=\"Nickzom Academy\" \/>\n<meta property=\"article:published_time\" content=\"2020-04-20T23:48:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-31T06:57:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/e63cc419-9772-46e8-9666-bc3c34333719.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Loveth Idoko\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Loveth Idoko\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/\"},\"author\":{\"name\":\"Loveth Idoko\",\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/#\\\/schema\\\/person\\\/c11f31e5522ed7e1ed0d78e7d9767042\"},\"headline\":\"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System\",\"datePublished\":\"2020-04-20T23:48:15+00:00\",\"dateModified\":\"2024-03-31T06:57:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/\"},\"wordCount\":900,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/e63cc419-9772-46e8-9666-bc3c34333719.jpeg\",\"keywords\":[\"design of gating system\",\"engineering\",\"foundry technology\",\"height of the cavity\",\"height of the sprue from its top to the point of metal entry into the mould cavity\",\"materials and metallurgical\",\"rated static head (for gating at mould parting)\"],\"articleSection\":[\"Engineering\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/\",\"url\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/\",\"name\":\"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/e63cc419-9772-46e8-9666-bc3c34333719.jpeg\",\"datePublished\":\"2020-04-20T23:48:15+00:00\",\"dateModified\":\"2024-03-31T06:57:07+00:00\",\"description\":\"Learn How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) in Design of Gating System with formulas and workings\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/e63cc419-9772-46e8-9666-bc3c34333719.jpeg\",\"contentUrl\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/e63cc419-9772-46e8-9666-bc3c34333719.jpeg\",\"width\":1024,\"height\":1024,\"caption\":\"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/2020\\\/04\\\/21\\\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/\",\"name\":\"Nickzom Academy\",\"description\":\"Unlock the power of learning: Dive into the world of calculations and excel in school education with Nickzom.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/#organization\",\"name\":\"Nickzom Academy\",\"url\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/wp-content\\\/uploads\\\/2023\\\/06\\\/icon-1024.png\",\"contentUrl\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/wp-content\\\/uploads\\\/2023\\\/06\\\/icon-1024.png\",\"width\":1024,\"height\":1024,\"caption\":\"Nickzom Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/#\\\/schema\\\/person\\\/c11f31e5522ed7e1ed0d78e7d9767042\",\"name\":\"Loveth Idoko\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b3148ea99bae69606b0ea410ab9e61588506bfe3590e761560389ac6cfb4b7f1?s=96&d=monsterid&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b3148ea99bae69606b0ea410ab9e61588506bfe3590e761560389ac6cfb4b7f1?s=96&d=monsterid&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b3148ea99bae69606b0ea410ab9e61588506bfe3590e761560389ac6cfb4b7f1?s=96&d=monsterid&r=g\",\"caption\":\"Loveth Idoko\"},\"sameAs\":[\"https:\\\/\\\/www.nickzom.org\"],\"url\":\"https:\\\/\\\/www.nickzom.org\\\/blog\\\/author\\\/loveth\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System","description":"Learn How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) in Design of Gating System with formulas and workings","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/","og_locale":"en_US","og_type":"article","og_title":"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System","og_description":"Learn How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) in Design of Gating System with formulas and workings","og_url":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/","og_site_name":"Nickzom Academy","article_published_time":"2020-04-20T23:48:15+00:00","article_modified_time":"2024-03-31T06:57:07+00:00","og_image":[{"width":1024,"height":1024,"url":"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/e63cc419-9772-46e8-9666-bc3c34333719.jpeg","type":"image\/jpeg"}],"author":"Loveth Idoko","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Loveth Idoko","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/#article","isPartOf":{"@id":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/"},"author":{"name":"Loveth Idoko","@id":"https:\/\/www.nickzom.org\/blog\/#\/schema\/person\/c11f31e5522ed7e1ed0d78e7d9767042"},"headline":"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System","datePublished":"2020-04-20T23:48:15+00:00","dateModified":"2024-03-31T06:57:07+00:00","mainEntityOfPage":{"@id":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/"},"wordCount":900,"commentCount":0,"publisher":{"@id":"https:\/\/www.nickzom.org\/blog\/#organization"},"image":{"@id":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/#primaryimage"},"thumbnailUrl":"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/e63cc419-9772-46e8-9666-bc3c34333719.jpeg","keywords":["design of gating system","engineering","foundry technology","height of the cavity","height of the sprue from its top to the point of metal entry into the mould cavity","materials and metallurgical","rated static head (for gating at mould parting)"],"articleSection":["Engineering"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/","url":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/","name":"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System","isPartOf":{"@id":"https:\/\/www.nickzom.org\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/#primaryimage"},"image":{"@id":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/#primaryimage"},"thumbnailUrl":"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/e63cc419-9772-46e8-9666-bc3c34333719.jpeg","datePublished":"2020-04-20T23:48:15+00:00","dateModified":"2024-03-31T06:57:07+00:00","description":"Learn How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) in Design of Gating System with formulas and workings","breadcrumb":{"@id":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/#primaryimage","url":"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/e63cc419-9772-46e8-9666-bc3c34333719.jpeg","contentUrl":"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2020\/04\/e63cc419-9772-46e8-9666-bc3c34333719.jpeg","width":1024,"height":1024,"caption":"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System"},{"@type":"BreadcrumbList","@id":"https:\/\/www.nickzom.org\/blog\/2020\/04\/21\/how-to-calculate-and-solve-for-rated-static-head-for-gating-at-mould-parting-design-of-gating-system\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.nickzom.org\/blog\/"},{"@type":"ListItem","position":2,"name":"How to Calculate and Solve for Rated Static Head (for Gating at Mould Parting) | Design of Gating System"}]},{"@type":"WebSite","@id":"https:\/\/www.nickzom.org\/blog\/#website","url":"https:\/\/www.nickzom.org\/blog\/","name":"Nickzom Academy","description":"Unlock the power of learning: Dive into the world of calculations and excel in school education with Nickzom.","publisher":{"@id":"https:\/\/www.nickzom.org\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.nickzom.org\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.nickzom.org\/blog\/#organization","name":"Nickzom Academy","url":"https:\/\/www.nickzom.org\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.nickzom.org\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2023\/06\/icon-1024.png","contentUrl":"https:\/\/www.nickzom.org\/blog\/wp-content\/uploads\/2023\/06\/icon-1024.png","width":1024,"height":1024,"caption":"Nickzom Academy"},"image":{"@id":"https:\/\/www.nickzom.org\/blog\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.nickzom.org\/blog\/#\/schema\/person\/c11f31e5522ed7e1ed0d78e7d9767042","name":"Loveth Idoko","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/b3148ea99bae69606b0ea410ab9e61588506bfe3590e761560389ac6cfb4b7f1?s=96&d=monsterid&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b3148ea99bae69606b0ea410ab9e61588506bfe3590e761560389ac6cfb4b7f1?s=96&d=monsterid&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b3148ea99bae69606b0ea410ab9e61588506bfe3590e761560389ac6cfb4b7f1?s=96&d=monsterid&r=g","caption":"Loveth Idoko"},"sameAs":["https:\/\/www.nickzom.org"],"url":"https:\/\/www.nickzom.org\/blog\/author\/loveth\/"}]}},"modified_by":"Joshua Abu","_links":{"self":[{"href":"https:\/\/www.nickzom.org\/blog\/wp-json\/wp\/v2\/posts\/3199","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.nickzom.org\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.nickzom.org\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.nickzom.org\/blog\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.nickzom.org\/blog\/wp-json\/wp\/v2\/comments?post=3199"}],"version-history":[{"count":0,"href":"https:\/\/www.nickzom.org\/blog\/wp-json\/wp\/v2\/posts\/3199\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.nickzom.org\/blog\/wp-json\/wp\/v2\/media\/13618"}],"wp:attachment":[{"href":"https:\/\/www.nickzom.org\/blog\/wp-json\/wp\/v2\/media?parent=3199"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.nickzom.org\/blog\/wp-json\/wp\/v2\/categories?post=3199"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.nickzom.org\/blog\/wp-json\/wp\/v2\/tags?post=3199"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}